Stair Layout
Menu

Stair Codes Compared: US, England, Germany, France, Spain

The US limits riser and tread, England adds a 42° pitch limit, and Germany checks the step rule 2s + a.

Stairs are built the same way everywhere, but the rules that limit them differ. The stair calculator checks the first three codes below. For the others, use the comfort mode and compare the results yourself.

All codes measure the riser between the tops of adjacent treads, and the tread depth (going) from the front edge of one tread to the front edge of the next.

The main limits

United States: IRC 2021 England: Approved Document K, private stair Germany: DIN 18065:2020-08, main stairs in a house
Riser at most 7 3/4 in (about 197 mm) 150 to 220 mm 14 to 20 cm
Tread depth (going) at least 10 in (254 mm) 220 to 300 mm 23 to 37 cm
Pitch or step rule no angle limit 2R + G 550 to 700 mm, pitch at most 42° 2s + a 59 to 65 cm
Headroom 6 ft 8 in (2.03 m) 2.0 m; 1.9 m at the centre in loft conversions not checked here
Width at least 36 in (914 mm) not checked here not checked here
Nosing 3/4 to 1 1/4 in when the tread is under 11 in not checked here not checked here

The details and references are on the code pages: IRC, Part K and DIN 18065.

Where the approaches differ

The US sets a maximum riser and a minimum tread and leaves the rest to the designer. A stair at both limits is about 37.8°. A single flight may rise at most 12 ft 7 in (3835 mm) between floors or landings (IRC 2021, R311.7.3).

England sets ranges for both rise and going, adds the 2R + G rule, and limits the pitch to 42°. Because of the pitch limit, a stair can meet the rise and going ranges and still fail: a 220 mm rise needs a going of at least 245 mm to stay at or under 42°.

Germany gives ranges for s and a in DIN 18065:2020-08, the current edition, and the step rule 2s + a = 59 to 65 cm keeps the combination comfortable. The ranges depend on the building and on whether the stair is required by the building code. For required stairs in the category “general buildings”, which can include the shared stairs of larger apartment blocks, Table 1, section 6.1.2 sets a riser of 14 to 19 cm and a going of 26 to 37 cm. Required stairs in houses with no more than two dwellings and inside dwellings have their own column, with the limits in the table above.

France

France has no single national limit for every stair inside a private house. The national accessibility rules depend on how the home will be used. A single-family house that the owner builds or renovates for their own use is exempt under article R162-5 of the Code de la construction et de l’habitation. Houses built to be let, sold or made available to others are covered. For homes on several levels that fall under the order of 24 December 2015, article 12 sets a riser of no more than 18 cm and a going of at least 24 cm for the stairs inside.

Shared stairs in new apartment buildings follow article 6.1: a riser of no more than 17 cm, a going of at least 28 cm and at least 1.00 m between handrails, measured to the central post where there is only one handrail and a central post. Buildings open to the public have their own rules. For comfort, designers commonly use Blondel’s formula, 2h + g between about 60 and 64 cm, with risers of about 16 to 18 cm. Use the comfort mode and check the rules that apply to your project.

Spain

In Spain, the Código Técnico de la Edificación, document DB SUA, section SUA 1, 4.1 and Annex A sets limits for stairs. Annex A counts the inside of a dwelling as restricted use, but not the shared areas of residential buildings. For restricted use, the tread must be at least 22 cm and the riser no more than 20 cm. Shared stairs in residential buildings and other stairs for general use have tighter limits. The calculator does not check the CTE yet: use the comfort mode and compare.

Canada, Australia and elsewhere

Canada uses the National Building Code as adopted by each province, and Australia the National Construction Code, each with its own limits. This version of the calculator does not check them. Use the comfort mode and ask your local building authority.

Codes change

Codes are revised every few years, and local authorities adopt them with amendments or keep older editions. The official text and your building authority decide what applies to you. The calculator’s results do not replace approval or a structural design.

  • Stair Calculator

    Enter the total rise. The calculator works out risers, treads and the stringer, and checks each rule of the building code you choose.

  • Stair Stringer Calculator

    Enter the total rise and your tread size. You get the cut for every step, the first and last cuts, and a template you can print at full size.

  • Stair Rise and Run Calculator

    Enter the total rise to get riser height and tread depth, then use the table to compare comfortable combinations.

  • Deck Stair Calculator

    Measure from the top of the deck to the surface where the stairs will land. The calculator works out the steps and lays out the stringers.

  • Stair Angle Calculator

    Enter the total rise and, if you know it, the total run. The angle of the stairs is shown first, with the steps that produce it.